2 Reasons to Think Twice Before Reporting 78070 With 78803
Sometimes CCI compliance requires looking beyond the edit pairs.
Correct Coding Initiative (CCI) edits don’t bundle SPECT (78803) and planar (78070) parathyroid imaging codes, but coding experts often tell you not to code the two together for SPECT and planar parathyroid imaging on the same date.
Add some method to this madness by looking at the information offered by two coding resources, the Society of Nuclear Medicine (SNM) and the NCCI Policy Manual for Medicare Services (CCI Manual).
1. SNM Singles Out 78803
SNM’s online Practice Management Coding Corner features a Q&A that recommends reporting 78070 (Parathyroid imaging) for planar imaging alone, but 78803 (Radiopharmaceutical localization of tumor or distribution of radiopharmaceutical agent[s]; tomographic) for parathyroid SPECT imaging with or without planar, says Jackie Miller, RHIA, CCS-P, CPC, vice president of product development for Coding Metrix Inc. in Powder Springs, Ga.
Support: “Choose the single code that describes the protocol and procedure performed,” states the Q&A, located at http://interactive.snm.org/index.cfm?PageID=2442&RPID=1995. SNM “would NOT recommend coding both CPT codes,” the article notes.
2. CCI Makes the Case for SPECT Code
Although there is notyou won’t find any a specific edit bundling 78070 and 78803, CCI does address the SPECT/planar issue in the CCI Manual, says Miller.
CCI Manual, Chapter 9, Section E.2, explains that you may not report a SPECT study and planar study of the same limited area because “Single photon emission computed tomography (SPECT) studies represent an enhanced methodology over standard planar nuclear imaging. When a limited anatomic area is studied, there is no additional information procured by obtaining both planar and SPECT studies.”
Bonus tip: The manual indicates you may report both planar and SPECT codes only when the size of the scanned area makes both sets necessary, such as with whole body bone scans with...